Abstract
Guided by ultrasonography percutaneous needle biopsy of skeletal muscle was performed in 24 patients, using the one hand held Biopty system and a 2 mm Tru-Cut needle. The specimens were graded with regard to diagnostic quality and utility and almost all specimens (96%) were of highest quality. The use of ultrasonography was helpful in selecting a suitable area for the biopsy and vascular structures could be avoided. The procedure was well tolerated and easy to perform, and no complications were recorded.
| Original language | English |
|---|---|
| Journal | Acta Radiologica |
| Volume | 31 |
| Issue number | 4 |
| Pages (from-to) | 411-3 |
| Number of pages | 3 |
| ISSN | 0284-1851 |