Kinetics of cardiac troponin and other biomarkers in patients with ST elevation myocardial infarction

Jonas Henrik Kristensen*, Clara Amalie Wistisen Koczulab, Emil Anton Frandsen, Rasmus Bo Hasselbalch, Nina Strandkjær, Nicoline Jørgensen, Morten Østergaard, Peter Hasse Møller-Sørensen, Jens Christian Nilsson, Shoaib Afzal, Pia Rørbæk Kamstrup, Morten Dahl, Mustafa Vakur Bor, Ruth Frikke-Schmidt, Niklas Rye Jørgensen, Line Rode, Lene Holmvang, Jesper Kjærgaard, Lia Evi Bang, Julie FormanKim Dalhoff, Henning Bundgaard, Kasper Karmark Iversen

*Corresponding author for this work

Research output: Contribution to journalJournal articleResearchpeer-review

48 Downloads (Pure)

Abstract

Objective: To examine changes in concentration, time-to-peak and the ensuing half-life of cardiac biomarkers in patients with myocardial infarction. Methods: Blood sampling was performed every third hour within 24 h after percutaneous coronary intervention (PCI) on a cohort of patients with ST elevation myocardial infarction. Cardiac troponin (cTn) was measured by the Dimension Vista, Vitros, Atellica, and Alinity high-sensitivity (hs) cTnI assays, and the Elecsys hs-cTnT assay. Further, creatine kinase (CK), myoglobin, creatine kinase MB (CKMB) and other biomarkers were analyzed. Results: A total of 36 patients completed blood sampling (median age 60 years, IQR 56.4–66.5 years; seven women, 19.4%). Hs-cTnI measured by the Vitros assay was the first hs-cTn to peak at 9.1 h (95%-CI 6.2–10.1) after PCI and 11.7 h (95%-CI 10.4–14.8) after symptoms onset. There were no notable differences between hs-cTn assays in regard to time-to-peak. Also, Vitros hs-cTnI reached the highest median ratio of concentration to upper reference level of nearly 2,000. The median half-life from peak concentration ranged from 7.6 h for myoglobin (CI 6.8–8.6) to 17.8 h for CK (CI 6.8–8.6). For hs-cTn assays the median T½ ranged from 12.4 h for the Vista hs-cTnI assay (95%-CI 11.0–14.1 h) to 17.3 h for the Elecsys hs-cTnT (95%-CI 14.9–20.8 h). Conclusions: This study updates knowledge on the kinetics of cardiac biomarkers in current clinical use. There was no notable difference in trajectories, time-to-peak or half-life between hs-cTn assays.

Original languageEnglish
Article number101250
JournalIJC Heart & Vasculature
Volume48
Number of pages8
ISSN2352-9067
DOIs
Publication statusPublished - Oct 2023

Bibliographical note

Publisher Copyright:
© 2023 The Authors

Keywords

  • Cardiac biomarkers
  • Cardiac troponin
  • Cohort study
  • Coronary artery disease
  • Kinetics
  • Myocardial infarction

Fingerprint

Dive into the research topics of 'Kinetics of cardiac troponin and other biomarkers in patients with ST elevation myocardial infarction'. Together they form a unique fingerprint.

Cite this