Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery

Michael Boelstoft Holte, Henrik Sæderup, Else Marie Pinholt*

*Corresponding author for this work

Research output: Contribution to journalJournal articleResearchpeer-review

73 Downloads (Pure)

Abstract

Objectives: The purpose of the present study was to validate and compare the accuracy and reliability of surface- and voxel-based registration on the mandibular rami for long-term three-dimensional (3D) evaluation of condylar remodelling following Orthognathic Surgery.

Methods: The mandible was 3D reconstructed from a pair of superimposed pre- and postoperative (two years) cone-beam computerized tomography scans and divided into the condyle, and 21 ramal regions. The accuracy of surface- and voxel-based registration was measured by the absolute mean surface distance of each region after alignment of the pre- and postoperative rami. To evaluate the reliability, mean absolute differences and intra class correlation coefficients (ICC) were calculated at a 95% confidence interval on volumetric and surface distance measurements of two observers. Paired t-tests were applied to statistically evaluate whether the accuracy and reliability of surface- and voxel-based registration were significantly different (p < 0.05).

Results: A total of twenty subjects (sixteen female; four male; mean age 27.6 years) with class II malocclusion and maxillomandibular retrognathia, who underwent bimaxillary surgery, were included. Surface-based registration was more accurate and reliable than voxel-based registration on the mandibular ramus two years post-surgery (p < 0.05). The inter observer reliability of using surface-based registration was excellent, ICC range [0.82–1.00]. For voxel-based registration, the inter observer reliability ranged from poor to excellent [0.00–0.98]. The measurement error introduced by applying surface-based registration for assessment of condylar remodelling was considered clinical irrelevant (1.83% and 0.18 mm), while the measurement error introduced by voxel-based registration was considered clinical relevant (5.44% and 0.52 mm).

Conclusions: Surface-based registration was proven more accurate and reliable compared to voxel-based registration on the mandibular ramus for long-term 3D assessment of condylar remodelling following Orthognathic Surgery. However, importantly, the performance difference may be caused by an inappropriate reference structure, proposed in the literature, and applied in this study.
Original languageEnglish
Article number20210499
JournalDentomaxillofacial Radiology
Volume51
Issue number4
Number of pages12
ISSN0250-832X
DOIs
Publication statusPublished - 1. May 2022

Keywords

  • Adult
  • Cone-Beam Computed Tomography/methods
  • Female
  • Humans
  • Imaging, Three-Dimensional/methods
  • Male
  • Mandible/diagnostic imaging
  • Mandibular Condyle/diagnostic imaging
  • Orthognathic Surgery
  • Reproducibility of Results
  • Three-Dimensional Imaging
  • Cone-Beam Computed Tomography
  • Temporomandibular Joint
  • Computer-Assisted Surgery

Fingerprint

Dive into the research topics of 'Comparison of surface- and voxel-based registration on the mandibular ramus for long-term three-dimensional assessment of condylar remodelling following orthognathic surgery'. Together they form a unique fingerprint.

Cite this