Skip to main navigation Skip to search Skip to main content

Coagulometer international sensitivity index (ISI) derivation, a rapid method using the prothrombin time/international normalized ratio (PT/INR) Line: A multicenter study

  • L. Poller*
  • , S. Ibrahim
  • , J. Jespersen
  • , A. Pattison
  • *Corresponding author for this work
  • University of Manchester
  • Hart Biologicals Ltd

Research output: Contribution to journal › Journal article › Research › peer-review

Abstract

Background: The original WHO procedure for prothrombin time (PT) standardization has been almost entirely abandoned because of the universal use of PT coagulometers. These often give different international normalized ratio (INR) results from the manual method, between individual makes of instruments and with instruments from the same manufacture. Method A simple procedure is required to derive local INR with coagulometers. The PT/INR Line method has recently been developed using five European Concerted Action on Anticoagulation (ECAA) certified plasmas to derive local INR. This procedure has been modified to derive a coagulometer PT/INR Line providing International Sensitivity Index (ISI) and mean normal PT (MNPT) for coagulometers and give local INR. Results have been compared with conventional ISI calibrations at the same laboratories. Results: With human thromboplastins, mean ISI by local calibration was 0.93 (range: 0.77-1.16). With the PT/INR Line, mean coagulometer ISI was higher, for example 0.99 (0.84-1.23) but using the PT/INR Line derived MNPT there was no difference in local INR. Between-centre INR variation of a certified validation plasma was reduced with human and bovine reagents after correction with local ISI calibrations and the PT/INR Line. Conclusion: The PT/INR Line-ISI with its derived MNPT is shown to provide reliable local INR with the 13 different reagent/coagulometer combinations at the 28 centres in this international study.

Original languageEnglish
JournalJournal of Thrombosis and Haemostasis
Volume10
Issue number7
Pages (from-to)1379-1384
ISSN1538-7933
DOIs
Publication statusPublished - Jul 2012

Keywords

  • Calibrant plasmas
  • Coagulometer
  • International normalized ratio
  • Mean normal prothrombin times
  • PT/INR Line
  • Thromboplastin

Fingerprint

Dive into the research topics of 'Coagulometer international sensitivity index (ISI) derivation, a rapid method using the prothrombin time/international normalized ratio (PT/INR) Line: A multicenter study'. Together they form a unique fingerprint.

Cite this