The validity of ultrasonographic scanning as screening method for abdominal aortic aneurysm

Jes Sanddal Lindholt, Sten Vammen, Søren Juul, E W Henneberg, H Fasting

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Resumé

the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultrasonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs.
OriginalsprogEngelsk
TidsskriftEuropean Journal of Vascular and Endovascular Surgery
Vol/bind17
Udgave nummer6
Sider (fra-til)472-5
Antal sider4
ISSN1078-5884
DOI
StatusUdgivet - 1999

Fingeraftryk

Abdominal Aortic Aneurysm

Citer dette

@article{d7d3de45dc624f85a93cd3fc5b1de39a,
title = "The validity of ultrasonographic scanning as screening method for abdominal aortic aneurysm",
abstract = "the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultrasonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs.",
keywords = "Aged, Aorta, Abdominal, Aortic Aneurysm, Abdominal, Denmark, Humans, Male, Mass Screening, Observer Variation, Predictive Value of Tests, Reproducibility of Results",
author = "Lindholt, {Jes Sanddal} and Sten Vammen and S{\o}ren Juul and Henneberg, {E W} and H Fasting",
note = "Copyright 1999 W.B. Saunders Company Ltd.",
year = "1999",
doi = "10.1053/ejvs.1999.0835",
language = "English",
volume = "17",
pages = "472--5",
journal = "European Journal of Vascular and Endovascular Surgery",
issn = "1078-5884",
publisher = "Elsevier",
number = "6",

}

The validity of ultrasonographic scanning as screening method for abdominal aortic aneurysm. / Lindholt, Jes Sanddal; Vammen, Sten; Juul, Søren; Henneberg, E W; Fasting, H.

I: European Journal of Vascular and Endovascular Surgery, Bind 17, Nr. 6, 1999, s. 472-5.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

TY - JOUR

T1 - The validity of ultrasonographic scanning as screening method for abdominal aortic aneurysm

AU - Lindholt, Jes Sanddal

AU - Vammen, Sten

AU - Juul, Søren

AU - Henneberg, E W

AU - Fasting, H

N1 - Copyright 1999 W.B. Saunders Company Ltd.

PY - 1999

Y1 - 1999

N2 - the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultrasonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs.

AB - the sensitivity and specificity of screening for abdominal aortic aneurysms (AAAs) with ultrasonographic scanning (US) is unknown. The aim of the study was to validate US as screening test for AAAs.

KW - Aged

KW - Aorta, Abdominal

KW - Aortic Aneurysm, Abdominal

KW - Denmark

KW - Humans

KW - Male

KW - Mass Screening

KW - Observer Variation

KW - Predictive Value of Tests

KW - Reproducibility of Results

U2 - 10.1053/ejvs.1999.0835

DO - 10.1053/ejvs.1999.0835

M3 - Journal article

C2 - 10375481

VL - 17

SP - 472

EP - 475

JO - European Journal of Vascular and Endovascular Surgery

JF - European Journal of Vascular and Endovascular Surgery

SN - 1078-5884

IS - 6

ER -