Strength of precast concrete shear joints reinforced with high-strength wire ropes

Henrik Brøner Jørgensen, Linh Cao Hoang, Lars German Hagsten

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Abstrakt

This paper concerns the in-plane shear strength of connections between precast concrete wall elements reinforced with looped high-strength wire ropes. The looped wire ropes are pre-installed in so-called ‘wire boxes’ which function as shear keys. Although only a small amount of research on the shear strength of such connections can be found in the literature, this type of connection is increasingly being used because wire ropes are much more construction-friendly than traditional U-bars. A rigid plastic upper bound model for the shear strength of wall connections reinforced with looped wire ropes that are pre-installed in wire boxes is presented along with test results on the shear strength of connections with double-wire boxes. It is shown that the plastic solution agrees well with both the obtained test results and results from previously conducted tests.
OriginalsprogEngelsk
TidsskriftProceedings of the Institution of Civil Engineers - Structures and Buildings
Vol/bind170
Udgave nummer3
Sider (fra-til)168-179
ISSN0965-0911
DOI
StatusUdgivet - 2017

Fingeraftryk Dyk ned i forskningsemnerne om 'Strength of precast concrete shear joints reinforced with high-strength wire ropes'. Sammen danner de et unikt fingeraftryk.

Citationsformater