TY - JOUR
T1 - Quantification of Cholesterol and Cholesteryl Ester by Direct Flow Injection High-Resolution Fourier Transform Mass Spectrometry Utilizing Species-Specific Response Factors
AU - Höring, Marcus
AU - Ejsing, Christer S
AU - Hermansson, Martin
AU - Liebisch, Gerhard
PY - 2019
Y1 - 2019
N2 - The quantification of free cholesterol (FC) and cholesteryl ester (CE) in mammalian samples is of great interest for basic science and clinical lipidomics. Here, we evaluated the feasibility of direct flow injection analysis (FIA) coupled to electrospray ionization high-resolution mass spectrometry (ESI-HRMS) to quantify FC and CE in lipid extracts from human serum, cultured cells, and mouse liver. Despite poor ionization efficiency of FC, the limit of quantitation was sufficient for precise and accurate quantification of FC by multiplexed HRMS (MSX) analysis without using a derivatization step. However, it was demonstrated that, upon full scan Fourier transform MS (FTMS) quantification, CE species show substantial differences in their analytical responses depending on number of double bonds, length of the acyl chain, infused lipid concentration, and other lipid components. A major determinant for these response differences is their susceptibility to in-source fragmentation. In particular, introduction of double bonds lowers the degree of in-source fragmentation. Therefore, CE species-specific response factors need to be applied for CE quantification by FTMS to achieve accurate concentrations. Method validation demonstrated that FIA-ESI-HRMS (MSX and FTMS) is applicable for quantification of FC and CE in samples used in basic science as well as clinical studies such as cultured cells, tissue homogenates, and serum.
AB - The quantification of free cholesterol (FC) and cholesteryl ester (CE) in mammalian samples is of great interest for basic science and clinical lipidomics. Here, we evaluated the feasibility of direct flow injection analysis (FIA) coupled to electrospray ionization high-resolution mass spectrometry (ESI-HRMS) to quantify FC and CE in lipid extracts from human serum, cultured cells, and mouse liver. Despite poor ionization efficiency of FC, the limit of quantitation was sufficient for precise and accurate quantification of FC by multiplexed HRMS (MSX) analysis without using a derivatization step. However, it was demonstrated that, upon full scan Fourier transform MS (FTMS) quantification, CE species show substantial differences in their analytical responses depending on number of double bonds, length of the acyl chain, infused lipid concentration, and other lipid components. A major determinant for these response differences is their susceptibility to in-source fragmentation. In particular, introduction of double bonds lowers the degree of in-source fragmentation. Therefore, CE species-specific response factors need to be applied for CE quantification by FTMS to achieve accurate concentrations. Method validation demonstrated that FIA-ESI-HRMS (MSX and FTMS) is applicable for quantification of FC and CE in samples used in basic science as well as clinical studies such as cultured cells, tissue homogenates, and serum.
U2 - 10.1021/acs.analchem.8b05013
DO - 10.1021/acs.analchem.8b05013
M3 - Journal article
C2 - 30707563
SN - 0003-2700
VL - 91
SP - 3459
EP - 3466
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 5
ER -