TY - JOUR
T1 - Modeling Electric Spark Discharges on Drones in Contact with High-Voltage Power Lines and Lab Equivalent Tests
AU - Hoang, Viet Duong
AU - Zhang, Hanchi
AU - McRae, Tim
AU - Leth Bak, Claus
AU - Ebeid, Emad
PY - 2025/12
Y1 - 2025/12
N2 - The use of drones for inspecting and maintaining high-voltage transmission lines has become increasingly popular, replacing traditional methods like helicopters and cranes. However, the potential difference between the drone and the high-voltage cable results in the occurrence of electric sparks striking the drone during its interaction with the power cable to perform tasks. This paper models the arcing phenomenon to predict spark current levels and repetition rates at any power line voltages and distances. Lab experiments at voltages up to 100 kV AC were conducted to validate the model, showing an accuracy range of 3.6% to 23% when considering the peak currents. The results were used to evaluate the interference to a carbon fiber drone in simulation and minimal shield was proposed to reduce the noise. All the proposed models are made available as open-source. Additionally, equivalent lab tests using at least two times lower voltages were introduced to replicate the arcing conditions of real overhead power lines.
AB - The use of drones for inspecting and maintaining high-voltage transmission lines has become increasingly popular, replacing traditional methods like helicopters and cranes. However, the potential difference between the drone and the high-voltage cable results in the occurrence of electric sparks striking the drone during its interaction with the power cable to perform tasks. This paper models the arcing phenomenon to predict spark current levels and repetition rates at any power line voltages and distances. Lab experiments at voltages up to 100 kV AC were conducted to validate the model, showing an accuracy range of 3.6% to 23% when considering the peak currents. The results were used to evaluate the interference to a carbon fiber drone in simulation and minimal shield was proposed to reduce the noise. All the proposed models are made available as open-source. Additionally, equivalent lab tests using at least two times lower voltages were introduced to replicate the arcing conditions of real overhead power lines.
U2 - 10.1109/TPWRD.2025.3606346
DO - 10.1109/TPWRD.2025.3606346
M3 - Journal article
SN - 0885-8977
VL - 40
SP - 3085
EP - 3097
JO - IEEE Transactions on Power Delivery
JF - IEEE Transactions on Power Delivery
IS - 6
ER -