Spring til hovednavigation Spring til søgning Spring til hovedindhold

Microcomputed tomography versus plethysmometer and electronic caliper in the measurements of lymphedema in the hindlimb of mice

Publikation: Bidrag til tidsskrift › Tidsskriftartikel › Forskning › peer review

47 Downloads (Pure)

Abstract

Lymphedema affects 20% of women diagnosed with breast cancer. It is a pathology with no known cure. Animal models are essential to explore possible treatments to understand and potentially cure lymphedema. The rodent hindlimb lymphedema model is one of the most widely used. Different modalities have been used to measure lymphedema in the hindlimb of mice, and these are generally poorly assessed in terms of the interrater agreement; thus, there could be a risk of measuring bias and poor reproducibility. We examined the interrater agreement of µCT-scans, electronic caliper thickness of the paw and plethysmometer in the measurement of lymphedema in the hindlimb of mice. Three independent raters assessed 24 C57BL6 mice using these three modalities four times (week 1, 2, 4 and 8) with a total of 96 samples. The mean interrater differences were then calculated. The interrater agreement was highest in the µCT-scans, with an extremely low risk of measurement bias. The interrater agreement in the plethysmometer and electronic caliper was comparable with a low to moderate risk of measurement bias. The µCT-scanner should be used whenever possible. The electronic caliper should only be used if there is no µCT-scanner available. The plethysmometer should not be used in rodents of this size.

OriginalsprogEngelsk
Artikelnummer12267
TidsskriftScientific Reports
Vol/bind12
Antal sider13
ISSN2045-2322
DOI
StatusUdgivet - 18. jul. 2022

Bibliografisk note

Funding Information:
Independent and unrestricted grants supporting the research project: Dagmar Marshalls Foundation, Aase and Ejnar Danielsens Foundation, Andersen-Isted Foundation, Jascha-Foundation, Else and Mogens Wedell-Wedellsborgs Foundation, Kai Lange and Gunhild Kai Langes Foundation.

Publisher Copyright:
© 2022, The Author(s).

Finansiering

Independent and unrestricted grants supporting the research project: Dagmar Marshalls Foundation, Aase and Ejnar Danielsens Foundation, Andersen-Isted Foundation, Jascha-Foundation, Else and Mogens Wedell-Wedellsborgs Foundation, Kai Lange and Gunhild Kai Langes Foundation.

Fingeraftryk

Dyk ned i forskningsemnerne om 'Microcomputed tomography versus plethysmometer and electronic caliper in the measurements of lymphedema in the hindlimb of mice'. Sammen danner de et unikt fingeraftryk.

Citationsformater