@inproceedings{468214910b15406fa5b9f51fb7749611,
title = "Measurement of the dielectric constant of liquids using a hybrid cavity-ring resonator",
abstract = "A simple and E&Plusmn;cient solution for extracting the dielectric constant of liquids utilizing microstrip ring resonators simultaneously with rectangular waveguide (RWG) cavities is presented. Employing both techniques in a single structure is a confirmation procedure rather than comparing the obtained results with any other standard method. The proposed structure is intended to be mechanically suited for holding liquid samples without enclosing any air gaps which enhances the measurement sensitivity. Since the structure is being totally enclosed, the loaded quality factor will be consequently increased due to the absence of radiation losses. The waveguide cavity acts as metallic enclosure for the ring circuit in order to maintain the design procedures as well.",
author = "Kheir, {M. S.} and Hammad, {H. F.} and Omar, {A. S.}",
year = "2008",
language = "English",
isbn = "9781618390547",
series = "Progress in Electromagnetics Research Symposium",
publisher = "Electromagnetics Academy",
pages = "552--555",
booktitle = "Progress in Electromagnetics Research Symposium 2008, PIERS 2008 Cambridge",
address = "United States",
note = "Progress in Electromagnetics Research Symposium 2008, PIERS 2008 Cambridge ; Conference date: 02-07-2008 Through 06-07-2008",
}