Abstract
The chemokine IP-10 (CXCL10) is a candidate marker for hepatitis C virus (HCV) fibrosis monitoring. The aim of this proof-of-concept study is to assess if IP-10 measurements from dried plasma spots (DPS) are accurate in HCV-infected patients with either minimal or significant fibrosis. We measured IP-10 levels in plasma and DPS of 21 HCV-infected patients with cirrhosis and 19 patients with no/little fibrosis (determined with FibroScan). Cirrhotic patients had significantly higher levels of IP-10 compared to patients with minimal fibrosis. DPS and plasma measurements of IP-10 are comparable and the correlation was excellent (r(2) = 0.97, p
| Originalsprog | Engelsk |
|---|---|
| Tidsskrift | PLOS ONE |
| Vol/bind | 7 |
| Udgave nummer | 9 |
| Sider (fra-til) | e45181 |
| ISSN | 1932-6203 |
| DOI | |
| Status | Udgivet - 2012 |