N2 - OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients.BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to intimal hyperplasia (IH).METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume.RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0.0-12.6) vs. 0.0 mm(3) (0.0-1.1), P = 0.001]. In-stent % volume obstruction was increased in EES compared to SES [median (interquartile range): 1.6% (0.0-8.2) vs. 0.0% (0.0-1.0), P = 0.001]. Peri-stent external elastic membrane (EEM) volume: (post procedure vs. follow-up EES [300 mm(3) (219-491) vs. 307 mm(3) (223-482), P = 0.73] and SES [316 mm(3) (235-399) vs. 323 mm(3) (246-404), P = 0.05]) and peri-stent plaque volume: EES [163 mm(3) (103-273) vs. 184 mm(3) (115-291), P = 0.18] and SES [186 mm(3) (139-248) vs. 175 mm(3) (153-243), P = 0.26]) were unchanged in both groups. In the proximal reference segment a significant increase in plaque area was seen in the EES group only, without vascular remodeling.CONCLUSION: In diabetic patients, EES stent implantation was associated with increased IH volume obstruction without involvement of vascular remodeling.
AB - OBJECTIVE: To evaluate the effects of the everolimus-eluting Xience™/Promus™ stent (EES) and the sirolimus-eluting Cypher™ stent (SES) on intimal hyperplasia (IH) in diabetic patients.BACKGROUND: Patients with diabetes mellitus have increased risk of in-stent restenosis after coronary stent implantation due to intimal hyperplasia (IH).METHODS: In a sub study of the Randomized Comparison of Everolimus-Eluting and Sirolimus-Eluting Stents in Patients Treated with Percutaneous Coronary Intervention (SORT OUT IV trial), serial intravascular ultrasound (IVUS) 10-month follow-up data were available in 88 patients, including 48 EES and 40 SES treated patients. IVUS endpoints included IH volume, in-stent % volume obstruction and changes in external elastic membrane (EEM) volume.RESULTS: Compared with the SES group, IH volume was increased in the EES group [median (interquartile range): 2.8 mm(3) (0.0-12.6) vs. 0.0 mm(3) (0.0-1.1), P = 0.001]. In-stent % volume obstruction was increased in EES compared to SES [median (interquartile range): 1.6% (0.0-8.2) vs. 0.0% (0.0-1.0), P = 0.001]. Peri-stent external elastic membrane (EEM) volume: (post procedure vs. follow-up EES [300 mm(3) (219-491) vs. 307 mm(3) (223-482), P = 0.73] and SES [316 mm(3) (235-399) vs. 323 mm(3) (246-404), P = 0.05]) and peri-stent plaque volume: EES [163 mm(3) (103-273) vs. 184 mm(3) (115-291), P = 0.18] and SES [186 mm(3) (139-248) vs. 175 mm(3) (153-243), P = 0.26]) were unchanged in both groups. In the proximal reference segment a significant increase in plaque area was seen in the EES group only, without vascular remodeling.CONCLUSION: In diabetic patients, EES stent implantation was associated with increased IH volume obstruction without involvement of vascular remodeling.
U2 - 10.1002/ccd.25180
DO - 10.1002/ccd.25180
M3 - Journal article
C2 - 23996918
VL - 83
SP - 864
EP - 872
JO - Catheterization and Cardiovascular Interventions
JF - Catheterization and Cardiovascular Interventions
SN - 1522-1946
IS - 6
ER -