Final report on the key comparison CCAUV.A-K3

Vicente Cutanda Henríquez, Knud Rasmussen

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

Resumé

Udgivelsesdato: 2006
OriginalsprogEngelsk
TidsskriftMetrologia
Vol/bind43
Antal sider84
ISSN0026-1394
DOI
StatusUdgivet - 1. jan. 2006
Udgivet eksterntJa

Fingeraftryk

Microphones
Acoustics
Calibration
Uncertainty

Citer dette

Cutanda Henríquez, Vicente ; Rasmussen, Knud. / Final report on the key comparison CCAUV.A-K3. I: Metrologia. 2006 ; Bind 43.
@article{23b41640645711ddb1a1000ea68e967b,
title = "Final report on the key comparison CCAUV.A-K3",
abstract = "This is the final report for key comparison CCAUV.A-K3 on the sensitivity calibration of laboratory standard microphones in the frequency range from 31.5 Hz to 31.5 kHz. Fifteen national measurement laboratories took part in this key comparison and the Centro Nacional de Metrolog{\'i}a (CENAM), Mexico, piloted the project with the assistance of the Danish Primary Laboratory for Acoustics (DPLA), Denmark. Four travelling standard microphones were circulated to the participants in two loops linked through the measurements of the CENAM and the DPLA. The participants' results in the form of sensitivity measurements (dB re 1 V/Pa) and full uncertainty budgets were collected throughout the project. Reference values for all four standard microphones have been calculated using a linear least squares minimization method. The differences between measurements and references have been averaged to obtain the degrees of equivalence per laboratory and interlaboratory. The deviations are all below 0.1 dB, except at 31.5 kHz. A frequency of 1000 Hz has been chosen to illustrate the degrees of equivalence. In all cases, the deviation is smaller than the associated uncertainty.",
author = "{Cutanda Henr{\'i}quez}, Vicente and Knud Rasmussen",
year = "2006",
month = "1",
day = "1",
doi = "10.1088/0026-1394/43/1A/09001",
language = "English",
volume = "43",
journal = "Metrologia",
issn = "0026-1394",
publisher = "IOP Publishing",

}

Final report on the key comparison CCAUV.A-K3. / Cutanda Henríquez, Vicente; Rasmussen, Knud.

I: Metrologia, Bind 43, 01.01.2006.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

TY - JOUR

T1 - Final report on the key comparison CCAUV.A-K3

AU - Cutanda Henríquez, Vicente

AU - Rasmussen, Knud

PY - 2006/1/1

Y1 - 2006/1/1

N2 - This is the final report for key comparison CCAUV.A-K3 on the sensitivity calibration of laboratory standard microphones in the frequency range from 31.5 Hz to 31.5 kHz. Fifteen national measurement laboratories took part in this key comparison and the Centro Nacional de Metrología (CENAM), Mexico, piloted the project with the assistance of the Danish Primary Laboratory for Acoustics (DPLA), Denmark. Four travelling standard microphones were circulated to the participants in two loops linked through the measurements of the CENAM and the DPLA. The participants' results in the form of sensitivity measurements (dB re 1 V/Pa) and full uncertainty budgets were collected throughout the project. Reference values for all four standard microphones have been calculated using a linear least squares minimization method. The differences between measurements and references have been averaged to obtain the degrees of equivalence per laboratory and interlaboratory. The deviations are all below 0.1 dB, except at 31.5 kHz. A frequency of 1000 Hz has been chosen to illustrate the degrees of equivalence. In all cases, the deviation is smaller than the associated uncertainty.

AB - This is the final report for key comparison CCAUV.A-K3 on the sensitivity calibration of laboratory standard microphones in the frequency range from 31.5 Hz to 31.5 kHz. Fifteen national measurement laboratories took part in this key comparison and the Centro Nacional de Metrología (CENAM), Mexico, piloted the project with the assistance of the Danish Primary Laboratory for Acoustics (DPLA), Denmark. Four travelling standard microphones were circulated to the participants in two loops linked through the measurements of the CENAM and the DPLA. The participants' results in the form of sensitivity measurements (dB re 1 V/Pa) and full uncertainty budgets were collected throughout the project. Reference values for all four standard microphones have been calculated using a linear least squares minimization method. The differences between measurements and references have been averaged to obtain the degrees of equivalence per laboratory and interlaboratory. The deviations are all below 0.1 dB, except at 31.5 kHz. A frequency of 1000 Hz has been chosen to illustrate the degrees of equivalence. In all cases, the deviation is smaller than the associated uncertainty.