T1 - Final five-year outcomes after implantation of biodegradable polymer-coated biolimus-eluting stents versus durable polymer-coated sirolimus-eluting stents
AU - Jakobsen, Lars
AU - Christiansen, Evald H.
AU - Maeng, Michael
AU - Hansen, Knud N.
AU - Kristensen, Steen D.
AU - Bøtker, Hans E.
AU - Terkelsen, Christian J.
AU - Jensen, Svend E.
AU - Raungaard, Bent
AU - Madsen, Morten
AU - Lassen, Jens F.
AU - Jensen, Lisette O.
AU - for the SORT OUT (Scandinavian Organization for Randomized Trials with Clinical Outcome) V investigators
PY - 2017
Y1 - 2017
N2 - Aims: Our aim was to report the long-term safety and efficacy of the biodegradable polymer-coated biolimus- eluting Nobori stent compared to the durable polymer-coated sirolimus-eluting CYPHER stent. Methods and results: SORT OUT V randomised 2,468 patients 1:1 to the Nobori (n=1,229) versus the CYPHER stent (n=1,239). Clinically driven event detection based on Danish registries was used. The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation). Individual components of the primary endpoint comprise the secondary endpoints. At five-year follow-up, the composite endpoint rate was found to be similar in patients treated with the two study stents (Nobori 182/1,229 [14.8%] vs. CYPHER 197/1,239 [15.8%]; odds ratio [OR] 0.93, 95% CI: 0.75-1.16; p=0.53). The rates of definite stent thrombosis were also found to be similar in patients treated with the two study stents (Nobori 23/1,229 [1.9%] vs. CYPHER 18/1,239 [1.5%]; OR 1.31, 95% CI: 0.70-2.47; p=0.40), as were the other secondary endpoints. Conclusions: At five-year follow-up, the Nobori stent with a biodegradable polymer coating provided a similar safety and efficacy profile when compared to the durable polymer first-generation CYPHER stent.
AB - Aims: Our aim was to report the long-term safety and efficacy of the biodegradable polymer-coated biolimus- eluting Nobori stent compared to the durable polymer-coated sirolimus-eluting CYPHER stent. Methods and results: SORT OUT V randomised 2,468 patients 1:1 to the Nobori (n=1,229) versus the CYPHER stent (n=1,239). Clinically driven event detection based on Danish registries was used. The primary endpoint was a composite of safety (cardiac death, myocardial infarction, definite stent thrombosis) and efficacy (target vessel revascularisation). Individual components of the primary endpoint comprise the secondary endpoints. At five-year follow-up, the composite endpoint rate was found to be similar in patients treated with the two study stents (Nobori 182/1,229 [14.8%] vs. CYPHER 197/1,239 [15.8%]; odds ratio [OR] 0.93, 95% CI: 0.75-1.16; p=0.53). The rates of definite stent thrombosis were also found to be similar in patients treated with the two study stents (Nobori 23/1,229 [1.9%] vs. CYPHER 18/1,239 [1.5%]; OR 1.31, 95% CI: 0.70-2.47; p=0.40), as were the other secondary endpoints. Conclusions: At five-year follow-up, the Nobori stent with a biodegradable polymer coating provided a similar safety and efficacy profile when compared to the durable polymer first-generation CYPHER stent.
KW - Drug-eluting stent
KW - In-stent restenosis
KW - Stent thrombosis