Abstract

Background: Despite the wide range of existing performance measures to evaluate functional status of patients with multiple sclerosis, the heterogeneous nature of the disease hinders clinical characterization and monitoring of disease severity. Speckle tracking ultrasonography is a non-invasive technique to assess isolated muscle function by evaluating the contractile properties of muscle tissue, i.e. muscle strain. The aim of this study was to investigate whether muscle strain measured by speckle tracking ultrasonography could be a useful quantitative measure of muscle function in patients with multiple sclerosis. The criterion validity of muscle strain was compared to that of validated performance measures of upper and lower extremity function. Methods: This cross-sectional study used baseline data from an explorative observational cohort study (the MUST study). Participants recruited from a hospital outpatient MS clinic underwent speckle tracking ultrasonography of the biceps brachii, supraspinatus, and soleus muscles of the dominant side according to pre-defined submaximal isometric contractions. Participants also completed the Timed 25-Foot Walk Test, the Six Spot Step Test, the 2-minute walking test, the Nine-Hole Peg Test, the 12-item Multiple Sclerosis Walking Scale, and the Oxford Shoulder Score. Gaussian distribution was investigated by visual inspection of normal probability plots and the Shapiro-Wilk test. The Timed 25-Foot Walk Test and Nine-Hole Peg Test were selected as gold standards for function of the lower and upper extremities, respectively. Criterion validity was assessed using Spearman's rank-order correlation coefficient ρ (rho), comparing the muscle strain and performance measures against predefined gold standards. Differences in criterion validity were estimated using squared correlations on the Fischer's Z-scale, with non-parametric bootstrapping to obtain bias-corrected, accelerated bootstrap confidence intervals (95% BCa). Results: Criterion validity showed good to excellent correlations between the gold standard for lower extremity function and the 2-minute walking test and Six Spot Step Test, and a fair correlation to the 12-item Multiple Sclerosis Walking Scale. No significant correlation was found between the gold standard for upper extremity function and the performance measure. There were no significant correlations between the gold standards and muscle strain. Conclusion: The absence of criterion validity for muscle strain alongside fair to strong criterion validity for the performance measures indicates that speckle tracking ultrasonography assessment of muscle strain is either invalid or evaluates other constructs of multiple sclerosis. Muscle strain assessed by speckle tracking ultrasonography cannot be recommended for the evaluation of treatment effects or disease progression in multiple sclerosis.

OriginalsprogEngelsk
Artikelnummer104478
TidsskriftMultiple Sclerosis and Related Disorders
Vol/bind70
Antal sider8
ISSN2211-0348
DOI
StatusUdgivet - feb. 2023

Bibliografisk note

Funding Information:
This work was funded by the University of Southern Denmark, the Region of Southern Denmark [grant number: 17/33583, 18/51851 ], Lounkaer Foundation, Augustinus’ Foundation [grant number: 18-0217 ], the Danish Multiple Sclerosis Society [grant number: A35607 ], Lily Benthine Lund's Foundation [grant number: 5652 ], the Society of Multiple Sclerosis Patients on Funen, the Chief Physician Committee Research Foundation [grant number: 70-A3228 ], and the Promotion of Medical Science Foundation [grant number: 18-L-0369 ]. The study sponsors have had no involvement in the study or influence on the reporting of the results.

Publisher Copyright:
© 2022

Fingeraftryk

Dyk ned i forskningsemnerne om 'Criterion validity of muscle strain analyses of skeletal muscle function in patients with multiple sclerosis'. Sammen danner de et unikt fingeraftryk.

Citationsformater