TY - JOUR
T1 - Comparison of local International Sensitivity Index calibration and 'Direct INR' methods in correction of locally reported International Normalized Ratios: an international study. On behalf of the European Action of Anticoagulation
AU - Poller, L
AU - Keown, M
AU - Ibrahim, S
AU - van den Besselaar, A M H P
AU - Roberts, C
AU - Stevenson, K
AU - Tripodi, A
AU - Pattison, A
AU - Jespersen, J
PY - 2007/5/1
Y1 - 2007/5/1
N2 - BACKGROUND: It is no longer feasible to check local International Normalized Ratios (INR) by the World Health Organization International Sensitivity Index (ISI) calibrations because the necessary manual prothrombin time technique required has generally been discarded. OBJECTIVES: An international collaborative study at 77 centers has compared local INR correction using the two alternative methods recommended in the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis guidelines: local ISI calibration and 'Direct INR'. METHODS: Success of INR correction by local ISI calibration and with Direct INR was assessed with a set of 27 certified lyophilized plasmas (20 from patients on warfarin and seven from normals). RESULTS: At 49 centers using human thromboplastins, 3.0% initial average local INR deviation from certified INR was reduced by local ISI calibration to 0.7%, and at 25 centers using rabbit reagents, from 15.9% to 7.5%. With a minority of commercial thromboplastins, mainly 'combined' rabbit reagents, INR correction was not achieved by local ISI calibration. However, when rabbit combined reagents were excluded the overall mean INR deviation after correction was reduced further to 3.9%. In contrast, with Direct INR, mean deviation using human thromboplastins increased from 3.0% to 6.6%, but there was some reduction with rabbit reagents from 15.9% to 10% (12.3% with combined reagents excluded). CONCLUSIONS: Local ISI calibration gave INR correction for the majority of PT systems but failed at the small number using combined rabbit reagents suggesting a need for a combined reference thromboplastin. Direct INR correction was disappointing but better than local ISI calibration with combined rabbit reagents. Interlaboratory variability was improved by both procedures with human reagents only
AB - BACKGROUND: It is no longer feasible to check local International Normalized Ratios (INR) by the World Health Organization International Sensitivity Index (ISI) calibrations because the necessary manual prothrombin time technique required has generally been discarded. OBJECTIVES: An international collaborative study at 77 centers has compared local INR correction using the two alternative methods recommended in the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis guidelines: local ISI calibration and 'Direct INR'. METHODS: Success of INR correction by local ISI calibration and with Direct INR was assessed with a set of 27 certified lyophilized plasmas (20 from patients on warfarin and seven from normals). RESULTS: At 49 centers using human thromboplastins, 3.0% initial average local INR deviation from certified INR was reduced by local ISI calibration to 0.7%, and at 25 centers using rabbit reagents, from 15.9% to 7.5%. With a minority of commercial thromboplastins, mainly 'combined' rabbit reagents, INR correction was not achieved by local ISI calibration. However, when rabbit combined reagents were excluded the overall mean INR deviation after correction was reduced further to 3.9%. In contrast, with Direct INR, mean deviation using human thromboplastins increased from 3.0% to 6.6%, but there was some reduction with rabbit reagents from 15.9% to 10% (12.3% with combined reagents excluded). CONCLUSIONS: Local ISI calibration gave INR correction for the majority of PT systems but failed at the small number using combined rabbit reagents suggesting a need for a combined reference thromboplastin. Direct INR correction was disappointing but better than local ISI calibration with combined rabbit reagents. Interlaboratory variability was improved by both procedures with human reagents only
KW - Calibration
KW - Humans
KW - International Normalized Ratio
KW - Internationality
KW - Sensitivity and Specificity
KW - World Health Organization
U2 - 10.1111/j.1538-7836.2007.02452.x
DO - 10.1111/j.1538-7836.2007.02452.x
M3 - Journal article
C2 - 17367490
SN - 1538-7933
VL - 5
SP - 1002
EP - 1009
JO - Journal of Thrombosis and Haemostasis
JF - Journal of Thrombosis and Haemostasis
IS - 5
ER -