Comparison of Image Quality and Quantification Parameters between Q.Clear and OSEM Reconstruction Methods on FDG-PET/CT Images in Patients with Metastatic Breast Cancer

Mohammad Naghavi-Behzad, Marianne Vogsen, Oke Gerke, Sara Elisabeth Dahlsgaard-Wallenius, Henriette Juel Nissen, Nick Møldrup Jakobsen, Poul-Erik Braad, Mie Holm Vilstrup, Paul Deak, Malene Grubbe Hildebrandt, Thomas Lund Andersen

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningpeer review

88 Downloads (Pure)

Abstract

We compared the image quality and quantification parameters through bayesian penalized likelihood reconstruction algorithm (Q.Clear) and ordered subset expectation maximization (OSEM) algorithm for 2-[ 18F]FDG-PET/CT scans performed for response monitoring in patients with metastatic breast cancer in prospective setting. We included 37 metastatic breast cancer patients diagnosed and monitored with 2-[ 18F]FDG-PET/CT at Odense University Hospital (Denmark). A total of 100 scans were analyzed blinded toward Q.Clear and OSEM reconstruction algorithms regarding image quality parameters (noise, sharpness, contrast, diagnostic confidence, artefacts, and blotchy appearance) using a five-point scale. The hottest lesion was selected in scans with measurable disease, considering the same volume of interest in both reconstruction methods. SUL peak (g/mL) and SUV max (g/mL) were compared for the same hottest lesion. There was no significant difference regarding noise, diagnostic confidence, and artefacts within reconstruction methods; Q.Clear had significantly better sharpness ( p < 0.001) and contrast ( p = 0.001) than the OSEM reconstruction, while the OSEM reconstruction had significantly less blotchy appearance compared with Q.Clear reconstruction ( p < 0.001). Quantitative analysis on 75/100 scans indicated that Q.Clear reconstruction had significantly higher SUL peak (5.33 ± 2.8 vs. 4.85 ± 2.5, p < 0.001) and SUV max (8.27 ± 4.8 vs. 6.90 ± 3.8, p < 0.001) compared with OSEM reconstruction. In conclusion, Q.Clear reconstruction revealed better sharpness, better contrast, higher SUV max, and higher SUL peak, while OSEM reconstruction had less blotchy appearance.

OriginalsprogEngelsk
Artikelnummer65
TidsskriftJournal of Imaging
Vol/bind9
Udgave nummer3
Antal sider11
ISSN2313-433X
DOI
StatusUdgivet - 9. mar. 2023

Fingeraftryk

Dyk ned i forskningsemnerne om 'Comparison of Image Quality and Quantification Parameters between Q.Clear and OSEM Reconstruction Methods on FDG-PET/CT Images in Patients with Metastatic Breast Cancer'. Sammen danner de et unikt fingeraftryk.

Citationsformater